云南华电昆明寻甸县马路坡150MW光伏发电项目安全设施验收评价报告
<table align="center" border="1" cellspacing="0" class="MsoTableGrid"> <tbody> <tr> <td width="170"> <p align="center"><span><span><span><span><span>项目名称</span></span></span></span></span></p> </td> <td colspan="2" width="214"> <p align="center"><span><span><span><span><span><span><span>云南华电昆明寻甸县马路坡</span><span>150MW</span></span></span><span><span><span>光伏</span></span></span><span><span><span>发电</span></span></span><span><span><span>项目</span></span></span><span><span><span>安全</span></span></span><span><span><span>设施验收评价</span></span></span><span><span><span>报告</span></span></span></span></span></span></span></p> </td> <td colspan="3" width="179"> <p align="center"><span><span><span><span><span>评价报告提交完成时间</span></span></span></span></span></p> </td> <td width="115"> <p align="center"><span><span><span><span><span>2024年2月</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>项目负责人</span></span></span></span></span></p> </td> <td colspan="2" width="214"> <p><span><span><span><span><span>罗亚中</span></span></span></span></span></p> </td> <td colspan="3" width="179"> <p align="center"><span><span><span><span><span>评价组组长</span></span></span></span></span></p> </td> <td width="115"> <p align="center"><span><span><span><span><span>罗亚中</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>评价组成员</span></span></span></span></span></p> </td> <td colspan="2" width="214"> <p align="justify"><span><span><span><span><span><span>罗亚中、杜福来、原虎军</span></span></span></span></span></span></p> </td> <td colspan="4" width="295"> <p><span><span><span><span><span>技术负责人</span></span></span><span><span><span>:</span></span></span><span><span><span>麦郁芃</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>现场勘查开始时间</span></span></span></span></span></p> </td> <td colspan="2" width="214"> <p align="center"><span><span><span><span><span>2023年8月2日</span></span></span></span></span></p> </td> <td colspan="2" width="125"> <p><span><span><span><span><span>现场勘查结束时间</span></span></span></span></span></p> </td> <td colspan="2" width="170"> <p align="center"><span><span><span><span><span>2023年8月2日</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>现场勘查人</span></span></span></span></span></p> </td> <td colspan="2" width="214"> <p align="center"><span><span><span><span><span>罗亚中、杜福来</span></span></span></span></span></p> </td> <td colspan="2" width="125"> <p><span><span><span><span><span>业主陪同人</span></span></span></span></span></p> </td> <td colspan="2" width="170"> <p align="center"><span><span><span><span><span>吕磊</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>企业属性</span></span></span></span></span></p> </td> <td colspan="6" width="510"> <p align="center"><span><span><span><span><span>光伏发电</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>现场勘查情况</span></span></span></span></span></p> </td> <td colspan="6" width="510"> <p align="center"><span><span><span><span><span>见附件</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>内审审核意见</span></span></span></span></span></p> </td> <td colspan="6" width="510"> <ol> <li><span><span><span><span><span><span><span>进一步补充、完善安全依据的法律、法规、标准和规范等内容,删除不涉及的依据;补充如《工业设备及管道防腐蚀工程技术标准》</span><span>GB/T50726-2023)等标准规范。补充2023年1月2日国家能源局《国家能源局综合司关于做好2023年风电、光伏发电开放建设有关事项的通知》(国能综通新能【2023】14号);2023年1月5日《国家能源局综合司关于开展可再生能源发电项目建档立卡工作的通知》、《国家电网公司光伏电站接入电网技术规定(Q/GDW617-2011)》、《分布式发电接入电网技术规定(Q/GDW480-2010)》等文件通知。(如果报告在10月1日后出。引用标准加上《安全生产严重失信主体名单管理办法》应急部令第11号)。</span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><a name="_Toc22723"><span>报告增加项目</span></a> <span>“防火区域划分”章节,并补充相关内容,以及对采取的相关安全对策措施符合性进行分析。</span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span>用图表形式补充项目火灾报警控制系统、消防监控系统,应急照明系统、及视频监控系统等安全设施设置情况列出,并进行相应符合性分析评价。</span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span>对评价项目区域如发生山火、暴雨、山洪、地质灾害等极端事件。补充相应危险有害因素分析,并对存在的安全隐患采取的安全对策措施符合性进行分析评价。</span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span>对评价项目区域如发生</span></span></span><span><span><span>雷击</span></span></span><span><span><span>等极端事件。补充相应危险有害因素分析,并对存在的安全隐患采取的安全对策措施符合性进行分析评价</span></span></span><span><span><span>。</span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span>补充项目清晰的平面方框布置图,并且</span></span></span><span><span><span>将项目相关建筑物之间,以及站外项目与村庄、道路、居民区等相关距离标示出来,并完善相应分析。</span></span></span><span><span><span>补充项目是否</span></span></span><span><span><span>设置有存储危险化学品六氟化硫的库房。如有,补充</span></span></span><span><span><span>分析库房</span></span></span><span><span><span>作为危险化学品储存的</span></span></span><span><span><span>相应危险有害因素分析,并对存在的安全隐患采取的安全对策措施符合性进行分析评价。</span></span></span><span><span><span>如危化品库房:</span><span>1.是否设置防止液体流散的设施;2.是否设置事故排风的排风口与机械送风系统;3.是否设置有毒气体检测报警装置;有毒气体检测报警信号是否送至有人值守的现场控制室、中心控制室等进行显示报警。4.是否符合相应危化品储存仓库其它相关要求等。</span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span>气体泄漏会造成人员中毒和窒息等事故。</span><span>1.补充</span></span></span><span><span><span>加压气体</span>SF6作业过程中危险有害因素分析,及对采取的相应防护措施(如装设SF6气体泄漏报警装置,并且定期进行校验合格;安装机械通风装置,并且排放口设置符合相关要求等)符合性进行分析;</span></span><span><span><span>2.补充</span></span></span><span><span><span>如果发生泄漏,企业相应的应急处置预案风险控制分析评价。。</span></span></span></span></span></span></span></li> </ol> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>过程控制审核意见</span></span></span></span></span></p> </td> <td colspan="6" width="510"> <p><span><span><span><span><span><span>按照电子版批注进行完善。</span></span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>技术负责人审核意见</span></span></span></span></span></p> </td> <td colspan="6" width="510"> <ol> <li><span><span><span><span><span>完善评价依据,删除失效或不适用的法规、标准,补充:《昆明市安全生产条例》、《石油化工可燃和有毒气体检测报警设计标准》(</span><span>GB/T50493-2019)、《光伏发电工程安全验收评价规程》(NB/T32038-2017)、《220kV~750kV变电站设计技术规程》(DL/T 5218-2018)等。</span></span></span></span></span></li> <li><span><span><span><span><span>核实并</span></span></span><span><span><span>补充说明以下</span></span></span><span><span><span>问题:</span></span></span><span><span>1、</span></span><span><span><span>是否设有储能装置;</span><span>2</span></span></span><span><span><span>、补充设备设施</span></span></span><span><span><span>清单;</span><span>3</span></span></span><span><span><span>、说明</span></span></span><span><span><span>S</span></span></span><span><span>VG室</span></span><span><span><span>的冷却方式;</span><span>4</span></span></span><span><span><span>、</span></span></span><span><span><span>补充说明防雷检测情况</span><span>5</span></span></span><span><span><span>、</span></span></span><span><span><span>补充说明消防验收情况(如果有)</span><span>6</span></span></span><span><span><span>、补充说明气体检测报警仪设</span></span></span><span><span><span>置情况;</span><span>7</span></span></span><span><span><span>、补充说明</span></span></span><span><span><span>35</span></span></span><span><span>kV</span></span><span><span><span>配电室事故风机及启动按钮设置情况;</span></span></span><span><span><span>8</span></span></span><span><span><span>、补充说明</span></span></span><span><span><span>涉及</span></span></span><span><span><span>油浸</span></span></span><span><span><span>变压器的各个位置事故油池设置的具体情况;</span></span></span><span><span><span>9</span></span></span><span><span><span>、补充说明火灾报警系统的具体情况(如烟</span></span></span><span><span><span>感还是温感、设置位置等);</span><span>1</span></span></span><span><span><span>0</span></span></span><span><span><span>、补充说明视频监控系统</span></span></span><span><span><span>情况。</span><span>1</span></span></span><span><span><span>1</span></span></span><span><span><span>、</span></span></span><span><span><span>光伏阵列区的隔离或围挡等设施设置情况。</span></span></span></span></span></li> <li><span><span><span><span><span>补充说明升</span></span></span><span><span><span>压站内各建构筑物及装置之间的距离。</span></span></span></span></span></li> <li><span><span><span><span><span>核实消防水池的容量。</span></span></span></span></span></li> <li><span><span><span><span><span>补充</span></span></span><span><span><span>升压站内各</span></span></span><span><span><span>电气</span></span></span><span><span><span>设备内外部安全净距的检查内容。</span></span></span></span></span></li> <li><span><span><span><span><span>补充各电气室的检查、评</span></span></span><span><span><span>价内容。</span></span></span></span></span></li> <li><span><span><span><span><span>补</span></span></span><span><span><span>充</span></span></span><span><span>GIS、六氟化硫断</span></span><span><span><span>路器区域气体检测报警仪、事故风机等的检查、评价内容。</span></span></span></span></span></li> <li><span><span><span><span><span>补充</span></span></span><span><span><span>建立双重预防机制、完善安全生产责任制体系、完善安全管理制度和安全操作规程、光伏阵列清洗和检维修、防山火、防游人或周边群众进入阵列区、消防设施维护、接地电阻定期检测等方面的对策措施建议。</span></span></span></span></span></li> <li><span><span><span><span><span>附件补充:安全投入台帐、新员工及转岗员工培训资料、日常安全教育和检查记录等。注意:图纸均需为签章齐全的竣工图。</span></span></span></span></span></li> <li><span><span><span><span><span>其余见报告标注。</span></span></span></span></span></li> </ol> </td> </tr> <tr> <td colspan="7" width="680"> <p align="center"><span><span><span><span><span>项目评价组人员组成</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>评价人员</span></span></span></span></span></p> </td> <td width="113"> <p align="center"><span><span><span><span><span>姓名</span></span></span></span></span></p> </td> <td colspan="3" width="226"> <p align="center"><span><span><span><span><span>资格证书号</span></span></span></span></span></p> </td> <td colspan="2" width="170"> <p align="center"><span><span><span><span><span>专业</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>项目负责人</span></span></span></span></span></p> </td> <td width="113"> <p align="center"><span><span><span><span><span>罗亚中</span></span></span></span></span></p> </td> <td colspan="3" width="226"> <p align="center"><span><span><span><span><span>S011053000110201000808</span></span></span></span></span></p> </td> <td colspan="2" width="170"> <p align="center"><span><span><span><span><span>无机非金属材料</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>报告编制人</span></span></span></span></span></p> </td> <td width="113"> <p align="center"><span><span><span><span><span>原虎军</span></span></span></span></span></p> </td> <td colspan="3" width="226"> <p align="center"><span><span><span><span><span>S01105300011020100807</span></span></span></span></span></p> </td> <td colspan="2" width="170"> <p align="center"><span><span><span><span><span>安全工程</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>报告编制人</span></span></span></span></span></p> </td> <td width="113"> <p align="center"><span><span><span><span><span>杜福来</span></span></span></span></span></p> </td> <td colspan="3" width="226"> <p align="center"><span><span><span><span><span>1800000000301214</span></span></span></span></span></p> </td> <td colspan="2" width="170"> <p align="center"><span><span><span><span><span>机械制造</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>报告审核人</span></span></span></span></span></p> </td> <td width="113"> <p align="center"><span><span><span><span><span>杨宏</span></span></span></span></span></p> </td> <td colspan="3" width="226"> <p align="center"><span><span><span><span>1200000000200822</span></span></span></span></p> </td> <td colspan="2" width="170"> <p align="center"><span><span><span><span><span>冶金药剂</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>过程控制负责人</span></span></span></span></span></p> </td> <td width="113"> <p align="center"><span><span><span><span><span>廖昆生</span></span></span></span></span></p> </td> <td colspan="3" width="226"> <p align="center"><span><span><span><span><span>0800000000205703</span></span></span></span></span></p> </td> <td colspan="2" width="170"> <p align="center"><span><span><span><span><span>化工工艺</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>技术负责人</span></span></span></span></span></p> </td> <td width="113"> <p align="center"><span><span><span><span><span>麦郁芃</span></span></span></span></span></p> </td> <td colspan="3" width="226"> <p align="center"><span><span><span><span><span>S</span></span></span><span><span><span>0</span></span></span><span><span><span>1105300011019100</span></span></span><span><span><span>1204</span></span></span></span></span></p> </td> <td colspan="2" width="170"> <p align="center"><span><span><span><span><span>机械制造工艺及设备</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>隐患名称</span></span></span></span></span></p> <p align="center"><span><span><span><span><span>(有几条写几条)</span></span></span></span></span></p> </td> <td colspan="2" width="214"> <ol> <li align="justify"><span><span><span><span><span><span><span><span>马路坡</span><span>150MW光伏发电项目对区域内的有限空间辨识不全,现场未设有相应的警示牌。2、马路坡150MW光伏发电项目部分光伏阵列区域外围未安全防护设围栏。3、部分光伏阵列区域靠农地范围、道路区域以及升压站站区内的安全警示告知牌不足。</span></span></span></span></span></span></span></span></li> </ol> </td> <td width="108"> <p align="center"><span><span><span><span><span>隐患等级</span></span></span></span></span></p> <p align="center"><span><span><span><span><span>(一般、重大)</span></span></span></span></span></p> </td> <td colspan="3" width="187"> <p><span><span><span><span><span>无重大隐患,一般隐患</span><span>3</span><span>条</span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>发现时间</span></span></span></span></span></p> </td> <td colspan="2" width="214"> <p align="justify"><span><span><span><span><span><span>2023年8月</span></span></span></span></span></span></p> </td> <td width="108"> <p align="center"><span><span><span><span><span>责任人</span></span></span></span></span></p> </td> <td colspan="3" width="187"> <p align="justify"><span><span><span><span><span><span>吕磊</span></span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>限期整改时间</span></span></span></span></span></p> </td> <td colspan="6" width="510"> <p align="justify"><span><span><span><span><span><span>两个月</span></span></span></span></span></span></p> </td> </tr> <tr> <td width="170"> <p><span><span><span><span><span>整改措施建议(条)</span></span></span></span></span></p> <p><span><span><span><span><span>(有几条写几条)</span></span></span></span></span></p> </td> <td colspan="6" width="510"> <ol> <li><span><span><span><span><span><span><span><span>建立极端天气预报制度,并联系气象部门对冰雹、特大风暴、雷暴、低温及积冰等极端天气做出预报。由大风引发的气象灾害预警发布纳入现有灾害性天气发布体系。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>电站在运行中,</span></span></span><span><span><span>应加强</span></span></span><span><span><span>检查电池板、逆变器、变压器、开关柜、直流系统、厂用电、继电保护等设备设施</span></span></span><span><span><span>及杆塔</span></span></span><span><span><span>、</span></span></span><span><span><span>光伏阵列</span></span></span><span><span><span>周边情况及标志牌和警示标志的定期检查,防止杆塔、</span></span></span><span><span><span>箱式</span></span></span><span><span><span>变压器</span></span></span><span><span><span>等</span></span></span><span><span><span>被破坏。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>运行人员应定期对</span></span></span><span><span><span>发电设备</span></span></span><span><span><span>、集电线路进行巡回检查,发现缺陷及时处理,并登记在缺陷记录本上。注意检查</span></span></span><span><span><span>箱式变压器</span></span></span><span><span><span>各部分是否渗油。另外,当气候异常、</span></span></span><span><span><span>发电设施</span></span></span><span><span><span>非正常运行、或新设备投入运行时,需要增加巡回检查内容及次数。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>在运行过程中定期对防雷接地装置进行检查测试,保持完好有效。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>变压器油系统油质应定期进行化验。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>根据《</span></span></span><span><span><span>工贸企业重大事故隐患判定标准</span></span></span><span><span><span>》</span></span></span><span><span><span>(</span></span></span><span><span><span>应急管理部</span><span>10号</span></span></span><span><span><span>)</span></span></span><span><span><span>第</span><span>13条</span></span></span><span><span><span>,</span></span></span><span><span><span>存在硫化氢、一氧化碳等中毒风险的有限空间作业的工贸企业有下列情形之一的,应当判定为重大事故隐患:(一)未对有限空间进行辨识、建立安全管理台账,并且未设置明显的安全警示标志的;(二)未落实有限空间作业审批,或者未执行</span><span>“先通风、再检测、后作业”要求,或者作业现场未设置监护人员的</span></span></span><span><span><span>。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>有限空间内盛装或者残留的物料对作业存在危害时,作业人员应当在作业前对物料进行清洗、清空或者置换。经检测,有限空间的危险有害因素符合《工作场所有害因素职业接触限值第一部分化学有害因素》(</span><span>GBZ2.1)的要求后,方可进入有限空间作业</span></span></span><span><span><span>。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>有限空间作业应办理作业票,</span> <span>经审批后方可进行作业;进行有限空</span> <span>间作业时,应严格遵守通风、检测合格后,再开展作业活动的安全管理要求;</span> <span>作业前应备足应急救援器材,</span> <span>作业时作业人员应正确使用防护用品;作业过</span> <span>程中,</span> <span>监护人应认真履行监护职责;发生事故时,</span> <span>不得盲目施救。</span> <span>应要确保</span> <span>救援人员安全的前提下,</span> <span>方可开展救援工作。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>登塔工作时佩带安全帽,系好安全带,同时穿结实防滑的胶底鞋,把维修用的工具、润滑油等放进确保无破损的工具包内,防止物体坠落</span></span></span><span><span><span>。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>高处作业人员应正确佩戴符合</span><span>GB6095要求的安全带及符合GB24543要求的安全绳;高处作业应设专人监护,作业人员不应在作业处休息。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>应根据实际需要配备符合安全要求的作业平台、吊笼、梯子、挡脚板、跳板等;脚手架的搭设、拆除和使用应符合</span><span>GB51210等有关标准要求。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>高处作业人员不应站在不牢固的结构物上进行作业;在彩钢板屋顶、石棉瓦、瓦楞板等轻型材料上作业,应铺设牢固的脚手板并加以固定,脚手板上要有防滑措施;不应在未固定、无防护设施的构件及管道上进行作业或通行。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>登高作业时,应先检查使用工器具的安全性,防止掉落伤人,登高时作业人员注意力应集中,严格按照规范佩戴防护用品。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>在大风的灾害性天气进行检修作业时,注意个人防护,防止机械构配件坠落伤人。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>对临时用电作业、高处作业等危险性较高的作业活动实施作业许可管理,严格履行审批手续。作业许可证应包含危害因素分析和安全措施等内容。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>应定期对升压站</span></span></span><span><span><span>、</span></span></span><span><span><span>光伏阵列</span></span></span><span><span><span>等</span></span></span><span><span><span>区域</span></span></span><span><span><span>进行防雷接地电阻检测,如发现接地电阻不合格时应及时进行整改,如发电机避雷器损坏或故障时应及时更换,确保防雷接地装置有效</span></span></span><span><span><span>。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>行路线选择时,路基路面宽度、弯道转弯半径、桥梁净空高度等必须满足组件、逆变器、箱变等大型设备的运输的通行要求。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>运输车辆必须经过相关部门的检验合格,不得使用有故障的车辆运输。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>驾驶员必须经过有关部门培训并取得相应车辆驾驶资格,严禁违章驾驶。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>严格按照规定运输,严禁超长、超重运输。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>大雨天气,车辆要严格限速,慢起步,匀速行使,采用抵挡制速。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>在电站进场道路上设置交通警示标志</span></span></span><span><span><span>。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>消防水系统压力表应定期进行检定</span></span></span><span><span><span>。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>现场应备有足够数量的灭火器材,灭火器应设置在明显和便于取用的地点,且不得影响安全疏散。灭火器应设置稳固,其铭牌必须朝外。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>灭火器不应设置在潮湿或强腐蚀性的地点,当必须设置时,应有相应的保护措施。设置在室外的灭火器,应有保护措施</span></span></span><span><span><span>。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>检修期间,严格执行逆变器、变压器、低压配电装置等检修规程和试验规程,并通过加强作业现场管理,落实两票三制。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>加强光伏组件基础、箱变基础的维护和保养,特别是根据系统的基础,做好防水排水。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>应定期对光伏电站周边环境进行巡查,发现周边村民在山林中用火等情况时及时进行劝阻和制止;雨季应加强对防排水设施的检查和维护。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>太阳能光伏组件场所应建立健全相应的安全警示牌以及制定相应的安全管理制度,并明确禁止无关人员、牲口进入光伏组件区域以及应定期对光伏组件区域的杂草进行清理等相关要求。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>光伏电站应设蓄电池组向继电保护、信号、自动装置等控制负荷和交流不间断电源装置、断路器合闸机构及直流事故照明等动力负荷供电,蓄电池组应以全浮充电方式运行</span></span></span><span><span><span>。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>采用酸性蓄电池蓄电池室和贮酸室应采用耐酸地面,其内墙面应涂耐酸漆或铺设耐酸材料。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>充电控制器应具有短路保护、过负荷保护、蓄电池过充(放)保护、欠(过)压保护及防雷保护功能,必要时应具备温度补偿、数据采集和通信功能</span></span></span><span><span><span>。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>光伏组件清洗过程中需要注意以下安全措施:</span></span></span><span><span><span>(</span></span></span><span><span><span>1</span></span></span><span><span><span>)</span></span></span><span><span> <span>禁止在高温环境下进行清洗,避免因温度突变导致组件损坏。</span></span></span><span><span><span>(</span></span></span><span><span><span>2</span></span></span><span><span><span>)</span></span></span><span><span><span>在确定光伏组件断开电源的情况下进行清洗,以避免触电事故。</span></span></span><span><span><span>(</span></span></span><span><span><span>3</span></span></span><span><span><span>)</span></span></span><span><span><span>使用</span></span></span><span><span><span>专用</span></span></span><span><span><span>的清洗工具和清洗剂,避免使用酸碱性强的化学品,以免对组件表面造成损坏。</span></span></span><span><span><span>(</span></span></span><span><span><span>4</span></span></span><span><span><span>)</span></span></span><span><span><span>在使用清洗工具时,避免使用过硬的刷子或带有金属螺丝等物,以防刮伤或损坏组件表面。</span></span></span><span><span><span>(</span></span></span><span><span><span>5</span></span></span><span><span><span>)</span></span></span><span><span><span>避免过度用力,以免造成组件损坏或组件框架变形。</span></span></span><span><span><span>(</span></span></span><span><span><span>6</span></span></span><span><span><span>)</span></span></span><span><span><span>注意清洗工作人员的安全,使用个人防护装备,如手套、防护眼镜等。</span></span></span><span><span><span>(</span></span></span><span><span><span>7</span></span></span><span><span><span>)</span></span></span><span><span><span>当有积水或湿滑的环境时,注意防滑,避免意外摔倒或滑动导致伤害。</span></span></span><span><span><span>(</span></span></span><span><span><span>8</span></span></span><span><span><span>)</span></span></span><span><span><span>进行清洗时,尽量避免直接照射太阳光,以免因温度急剧变化而对组件造成热应力。</span></span></span><span><span><span>(</span></span></span><span><span><span>9</span></span></span><span><span><span>)</span></span></span><span><span><span>执行清洗工作时,遵循相关安全操作规程和操作指南,确保操作的安全性和有效性</span></span></span><span><span><span>。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>光伏组件应定期检查,若发现下列问题应立即调整或更换光伏组件;(</span><span>1)光伏组件存在玻璃破碎、背板灼焦、明显的颜色变化;(2)光伏组件中存在与组件边缘或任何电路之间形成连通通道的气泡;(3)光伏组件接线盒变形、扭曲。开裂或烧毁,接线端子无法良好连接</span></span></span><span><span><span>。</span></span></span></span></span></span></span></span></li> <li><span><span><span><span><span><span><span><span>为防止山火对光伏电站造成影响,建议在光伏电站周边设立防火隔离带;加强巡查、及时清除站内及光伏设施周边的杂草。</span></span></span></span></span></span></span></span></li> </ol> <p> </p> </td> </tr> <tr> <td width="170"> <p align="center"><span><span><span><span><span>评价项目评价结论</span></span></span></span></span></p> </td> <td colspan="6" width="510"> <p><span><span><span><span><span>云南华电昆明寻甸县马路坡</span><span>150MW光伏发电项目告项目符合国家法律、法规、标准、行政规章、规范的安全要求,具备安全设施竣工验收的条件。</span></span></span></span></span></p> </td> </tr> </tbody> </table> <p><span>现场照片</span></p> <p><img alt="" height="452" src="https://omo-oss-image.thefastimg.com/portal-saas/pg2025102117473232840/cms/image/0f11c88d-7308-4bb7-b0c6-db338f1348ac.png" width="685"></p> <p>评价人员与业主代表照片 </p> <p><img alt="" height="498" src="https://omo-oss-image.thefastimg.com/portal-saas/pg2025102117473232840/cms/image/5c379a26-7daf-4341-add5-da1394efa403.png" width="667"></p> <p><span><span><img alt="" src="file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml5900\wps1.png"></span></span></p> <p> </p>