YNAY-AP(现状)-2025-083 昆明鼎燃石化有限公司金尚加油站安全现状评价报告


<link href="https://m2cdn.fastindexs.com/npmanager/static/lib/ckeditor5/preview.css?v=1.3.053" rel="stylesheet" /><p class="MsoSubtitle" style="text-align:center;"><span><strong>安全评价报告信息公开</strong></span></p><p style="text-align:center;"><span>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; YNAY/R(AP)-2025-014</span></p><figure class="table"><table class="Table" align="center" border="1" cellspacing="0"><tbody><tr><td width="114"><p style="text-align:center;"><span>机构名称</span></p></td><td colspan="3" width="265"><p style="text-align:center;"><span>云南安益安全评价有限公司</span></p></td><td width="111"><span>资质证书编号</span></td><td width="156"><p style="text-align:center;"><span>APJ-(云)-004</span></p></td></tr><tr><td width="114"><p style="text-align:center;"><span>项目名称</span></p></td><td colspan="5" width="532"><p style="text-align:center;"><span>昆明鼎燃石化有限公司金尚加油站安全现状评价报告</span></p></td></tr><tr><td width="114"><p style="text-align:center;"><span>评价类别</span></p></td><td colspan="5" width="532"><p style="text-align:center;"><span>预评价□ &nbsp;&nbsp;验收评价□ &nbsp;现状评价☑&nbsp;&nbsp; 其他安全评价□</span></p></td></tr><tr><td width="114"><p class="p" style="text-align:center;"><span>项目简介</span></p></td><td colspan="5" width="532"><p class="p" style="text-align:justify;"><span>加油区设罩棚1座,为钢架结构,耐火等级为二级,罩棚净空高度约4.8m。罩棚下设单柱加油岛4座,宽为1.2m,高出地面0.2m,罩棚共设支柱4根,每个加油岛上设一台加油机,共计4台四枪加油机,加油机设单机急停按钮,汽油加油机设置油气回收系统。加油岛外侧设防撞栏,加油岛防撞栏高度约1m,罩棚下设单车道2条,宽度为5m、4m,双车道1条,宽度为7m。</span></p><p class="p" style="text-align:justify;"><span>油罐区设置于加油区西北面,油罐区1个30m3卧式95#汽油储罐、1个50m3卧式92#汽油储罐、1个30m3卧式柴油储罐,油罐为单层钢制油罐,布置在防渗罐池内。罐顶覆土约0.9m,油罐的人孔设置有操作井,操作井底部及四壁采用瓷砖贴面防渗。油罐通气管设置于加油区罩棚支柱内,通气管管口高出罩棚顶面1.5m,管口安装有阻火器。加油根据《汽车加油加气加氢站技术标准》(GB50156-2021)中加油站等级划分标准,按现用储罐容积,该加油站为二级加油站。</span></p><p class="p" style="text-align:justify;"><span>加油站管道均采用无缝钢管,埋地油罐与露出地面的工艺管道相互做静电连接并接地,油品管道上的法兰的连接螺栓,法兰、胶管两端等连接处用铜片跨接。油罐车卸油时用的卸油连通软管采用导静电耐油软管。连通软管的公称直径为80mm。加油站内的工艺管道均埋地敷设,且未穿过站房等建构筑物。</span></p><p class="p" style="text-align:justify;"><span>密闭卸油点设置于罐区西南面,站房西北面,卸油口地面采用瓷砖贴面防渗,卸油口处设有罐车卸车时用的移动式防静电接地报警装置。设置密闭卸油口3个,油气回收口1个。每个油罐分别设置卸油接口,卸油口与油气回收口做并联并接地,每个接口上有明显的油品标识。汽油卸油接口装设快速阳接头及密封盖,柴油卸油接口装设快速阴接头及密封盖。卸油平台设置于加油站卸油口的西北面,与密闭卸油点相邻。</span></p><p class="p" style="text-align:justify;"><span>一层站房位于加油区西南面,布置为营业室兼便利店。一层辅房现用作杂物房。</span></p></td></tr><tr><td width="114"><p class="p" style="text-align:center;"><span>项目负责人</span></p></td><td width="110"><p class="p" style="text-align:center;"><span>保家超</span></p></td><td width="128"><p class="p" style="text-align:center;"><span>项目组成员</span></p></td><td colspan="3" width="294"><p style="text-align:center;"><span>蒋济桧、许云谱、尹翔、罗智</span></p></td></tr><tr><td width="114"><p class="p" style="text-align:center;"><span>报告编制人</span></p></td><td width="110"><p class="p" style="text-align:center;"><span>蒋济桧、许云谱、尹翔、罗智</span></p></td><td width="128"><p class="p" style="text-align:center;"><span>报告审核人</span></p></td><td colspan="3" width="294"><p style="text-align:center;"><span>夏韬</span></p></td></tr><tr><td width="114"><p class="p" style="text-align:center;"><span>技术负责人</span></p></td><td width="110"><p class="p" style="text-align:center;"><span>刘涛</span></p></td><td width="128"><p class="p" style="text-align:center;"><span>过程控制负责人</span></p></td><td colspan="3" width="294"><p style="text-align:center;"><span>廖昆生</span></p></td></tr><tr><td width="114"><p class="p" style="text-align:center;"><span>技术专家</span></p></td><td colspan="5" width="532"><p style="text-align:center;"><span>\</span></p></td></tr><tr><td width="114"><p class="p" style="text-align:center;"><span>现场开展评价工作人员</span></p></td><td colspan="5" width="532"><p style="text-align:center;"><span>保家超、罗智</span></p></td></tr><tr><td width="114"><p class="p" style="text-align:center;"><span>勘察时间</span></p></td><td colspan="5" width="532"><p style="text-align:center;"><span>2025年6月3日</span></p></td></tr><tr><td width="114"><p class="p" style="text-align:center;"><span>报告结论</span></p></td><td colspan="5" width="532"><p style="text-align:center;"><span>经营现状符合国家相关法律、法规及标准、规范对危险化学品经营单位的安全要求。</span></p></td></tr><tr><td width="114"><p class="p" style="text-align:center;"><span>评价报告</span></p><p class="p" style="text-align:center;"><span>提交时间</span></p></td><td colspan="5" width="532"><p style="text-align:center;"><span>2025年8月</span></p></td></tr><tr><td width="114"><p class="p" style="text-align:center;"><span>评审组织单位</span></p></td><td colspan="5" width="532"><p style="text-align:center;"><span>\</span></p></td></tr><tr><td width="114"><p class="p" style="text-align:center;"><span>现场照片</span></p></td><td colspan="5" width="532"><p style="text-align:center;"><span>现场调查及影像资料(含企业名称或标识的合影照片)</span></p><p><span><img src="file:///C:\Users\ADMINI~1\AppData\Local\Temp\ksohtml12520\wps2.png" alt=""></span><img src="https://omo-oss-image.thefastimg.com/portal-saas/pg2025102117473232840/cms/image/a50a72aa-1f22-4094-a1bc-41460fc27f20.png" alt="" height="439" width="543"><span><img src="file:///C:\Users\ADMINI~1\AppData\Local\Temp\ksohtml12520\wps3.png" alt=""></span></p><p style="text-align:center;"><span>左:受评企业代表,中:项目负责人保家超,右:评价人员罗智</span></p></td></tr></tbody></table></figure>