YNAY-AP(现状)-2022-027 呈贡马郎加油站安全现状评价
<link href="https://m2cdn.fastindexs.com/npmanager/static/lib/ckeditor5/preview.css?v=1.3.053" rel="stylesheet" /><p><img src="https://omo-oss-image.thefastimg.com/portal-saas/pg2025102117473232840/cms/image/094f2345-f1a1-4654-89e0-db49e3f2882f.jpg" alt="" height="4677" width="3307"></p><figure class="table"><table class="MsoTableGrid" align="center" border="1" cellspacing="0"><tbody><tr><td colspan="2" width="173"><p style="text-align:center;"><span>项目名称</span></p></td><td colspan="6" width="185"><p style="text-align:center;"><span>呈贡马郎加油站</span></p></td><td colspan="4" width="224"><p style="text-align:center;"><span>评价报告提交完成时间</span></p></td><td width="115"><p style="text-align:center;"><span>2025年4月</span></p></td></tr><tr><td colspan="2" width="173"><p style="text-align:center;"><span>项目负责人</span></p></td><td colspan="6" width="185"><p style="text-align:center;"><span>保家超</span></p></td><td colspan="3" width="170"><p style="text-align:center;"><span>评价组组长</span></p></td><td colspan="2" width="169"><p style="text-align:center;"><span>保家超</span></p></td></tr><tr><td colspan="2" width="173"><p style="text-align:center;"><span>评价组成员</span></p></td><td colspan="6" width="185"><p style="text-align:center;"><span>罗智</span></p></td><td colspan="3" width="170"><p style="text-align:center;"><span>技术负责人</span></p></td><td colspan="2" width="169"><p style="text-align:center;"><span>刘涛</span></p></td></tr><tr><td colspan="2" width="173"><p style="text-align:center;"><span>现场勘查开始时间</span></p></td><td colspan="6" width="185"><p style="text-align:center;"><span>2025年2月19日</span></p></td><td colspan="3" width="170"><p style="text-align:center;"><span>现场勘查结束时间</span></p></td><td colspan="2" width="169"><p style="text-align:center;"><span>2025年2月19日</span></p></td></tr><tr><td colspan="2" width="173"><p style="text-align:center;"><span>现场勘查人</span></p></td><td colspan="6" width="185"><p style="text-align:center;"><span>罗智</span></p></td><td colspan="3" width="170"><p style="text-align:center;"><span>业主陪同人</span></p></td><td colspan="2" width="169"><p style="text-align:center;"><span>张靖</span></p></td></tr><tr><td colspan="2" width="173"><p style="text-align:center;"><span>现场勘查情况</span></p></td><td colspan="11" width="525"><p><span> 加油站座东南朝西北,站址东北面有二层民房;东南面站内洗车机,站外为马郎小学(2022年现状评价时由于油罐区与马郎小学安全间距不足,由加油站出资,在马郎小学内距离加油站油罐35m位置设置一圈隔离栏,防止师生进入加油站油罐35m范围内),西南面有三层民房,西北面为三铝公路,加油站东北、东南、西南面设置围墙与周围隔离。</span></p><p><span> 加油区设罩棚1座,净空高度7m。罩棚下设单柱加油岛5座,宽为1.5m,高出地面0.2m,罩棚支柱设在加油岛上,加油岛共设双枪加油机5台,汽油加油机设置油气回收系统。罩棚下设单车道2条,宽度分别为7m/8m,双车道1条,宽度12m。</span></p><p><span> 油罐区设置于站房东面,油罐区30m3的92#汽油储罐1个;30m3的95#汽油储罐1个(分为两个隔舱,分别为18m3和12m3,均储存95#汽油);50m3的0#柴油埋地储罐1个,罐顶覆土约0.5m,油罐的人孔设置有操作井。油罐通气管设置于油罐区内,高出地面4.5m,通气管口安装有阻火器。</span></p></td></tr><tr><td colspan="2" width="173"><p style="text-align:center;"><span>内审审核意见</span></p></td><td colspan="11" width="525"><p style="text-align:center;"><span>已通过内部审核</span></p></td></tr><tr><td colspan="2" width="173"><p style="text-align:center;"><span>过程控制审核意见</span></p></td><td colspan="11" width="525"><p style="text-align:center;"><span>已按要求完成内部控制程序</span></p></td></tr><tr><td colspan="2" width="173"><p style="text-align:center;"><span>技术负责人审核意见</span></p></td><td colspan="11" width="525"><p style="text-align:center;"><span>已通过技术审核</span></p></td></tr><tr><td colspan="13" width="698"><p style="text-align:center;"><span>参加评价人员情况</span></p></td></tr><tr><td colspan="3" width="174"><p style="text-align:center;"><span>姓 名</span></p></td><td colspan="3" width="174"><p style="text-align:center;"><span>职业证书编号</span></p></td><td colspan="4" width="174"><p style="text-align:center;"><span>资质等级</span></p></td><td colspan="3" width="174"><p style="text-align:center;"><span>承担的主要工作</span></p></td></tr><tr><td colspan="3" width="174"><p style="text-align:center;"><span>保家超</span></p></td><td colspan="3" width="174"><p style="text-align:center;"><span>S011053000110192002950</span></p></td><td colspan="4" width="174"><p style="text-align:center;"><span>二级</span></p></td><td colspan="3" width="174"><p style="text-align:center;"><span>项目负责人</span></p></td></tr><tr><td colspan="3" width="174"><p style="text-align:center;"><span>蒋济桧</span></p></td><td colspan="3" width="174"><p style="text-align:center;"><span>S011053000110192002955</span></p></td><td colspan="4" width="174"><p style="text-align:center;"><span>二级</span></p></td><td colspan="3" width="174"><p style="text-align:center;"><span>报告编制人</span></p></td></tr><tr><td colspan="3" width="174"><p style="text-align:center;"><span>许云谱</span></p></td><td colspan="3" width="174"><p style="text-align:center;"><span>S011053000110202001821</span></p></td><td colspan="4" width="174"><p style="text-align:center;"><span>二级</span></p></td><td colspan="3" width="174"><p style="text-align:center;"><span>报告编制人</span></p></td></tr><tr><td colspan="3" width="174"><p style="text-align:center;"><span>尹 翔</span></p></td><td colspan="3" width="174"><p style="text-align:center;"><span>1700000000301629832</span></p></td><td colspan="4" width="174"><p style="text-align:center;"><span>二级</span></p></td><td colspan="3" width="174"><p style="text-align:center;"><span>报告编制人</span></p></td></tr><tr><td colspan="3" width="174"><p style="text-align:center;"><span>罗 智</span></p></td><td colspan="3" width="174"><p style="text-align:center;"><span>1100000000301629</span></p></td><td colspan="4" width="174"><p style="text-align:center;"><span>三级</span></p></td><td colspan="3" width="174"><p style="text-align:center;"><span>报告编制人</span></p></td></tr><tr><td colspan="2" width="173"><p style="text-align:center;"><span>一般隐患数(条数)</span></p></td><td colspan="3" width="173"><p style="text-align:center;"><span>8</span></p></td><td colspan="4" width="172"><p style="text-align:center;"><span>重大隐患数(条数)</span></p></td><td colspan="4" width="179"><p style="text-align:center;"><span>0</span></p></td></tr><tr><td width="133"><p style="text-align:center;"><span>隐患名称</span></p></td><td colspan="4" width="213"><p class="MsoBodyTextFirstIndent"><span>1、加油机油气回收检测口未采用丝堵封堵。</span></p><p class="MsoBodyTextFirstIndent"><span>2、卸油口底部未作防渗处理。</span></p><p class="MsoBodyTextFirstIndent"><span>3、人体静电导除装置无声光报警。</span></p><p class="MsoBodyTextFirstIndent"><span>4、操作井加油油气回收管标识错误。</span></p><p class="MsoBodyTextFirstIndent"><span>5、手提式灭火器应更换为5kg装。</span></p><p class="MsoBodyTextFirstIndent"><span>6、发电机油箱下未设置接渗措施。</span></p><p class="MsoBodyTextFirstIndent"><span>7、UPS损坏未使用。</span></p><p class="MsoBodyTextFirstIndent"><span>8、部分视频监控探头无信号。</span></p></td><td colspan="4" width="172"><p style="text-align:center;"><span>隐患等级(一般、重大)</span></p></td><td colspan="4" width="179"><p style="text-align:center;"><span>一般</span></p></td></tr><tr><td width="133"><p style="text-align:center;"><span>发现时间</span></p></td><td colspan="4" width="213"><p style="text-align:center;"><span>2025年2月19日</span></p></td><td colspan="4" width="172"><p style="text-align:center;"><span>责任人</span></p></td><td colspan="4" width="179"><p style="text-align:center;"><span>张靖</span></p></td></tr><tr><td width="133"><p style="text-align:center;"><span>限期整改时间</span></p></td><td colspan="12" width="565"><p style="text-align:center;"><span>2025年4月15日</span></p></td></tr><tr><td width="133"><p style="text-align:center;"><span>整改措施建(条)</span></p></td><td colspan="3" width="124"><p style="text-align:center;"><span>8</span></p></td><td colspan="3" width="99"><p style="text-align:center;"><span>具体内容</span></p></td><td colspan="6" width="340"><p><span>1、加油机油气回收检测口未采用丝堵封堵。</span></p><p><span>2、卸油口底部未作防渗处理。</span></p><p><span>3、人体静电导除装置无声光报警。</span></p><p><span>4、操作井加油油气回收管标识错误。</span></p><p><span>5、手提式灭火器应更换为5kg装。</span></p><p><span>6、发电机油箱下未设置接渗措施。</span></p><p><span>7、UPS损坏未使用。</span></p><p><span>8、部分视频监控探头无信号。</span></p></td></tr><tr><td width="133"><p style="text-align:center;"><span>评价项目评价结论</span></p></td><td colspan="12" width="565"><span>呈贡马郎加油站的安全评价结论为:<strong>其经营现状符合国家相关法律、法规及标准、规范对危险化学品经营单位的安全要求。</strong></span></td></tr></tbody></table></figure><p style="text-align:center;"> </p><p style="text-align:center;">现场照片</p><p style="text-align:center;"><img class="image_resized" style="width:77.52%;" src="https://omo-oss-image.thefastimg.com/portal-saas/pg2025102117473232840/cms/image/7aaf2166-2d83-47d5-9c46-2c324c8b6f77.jpg" alt="" height="521" width="695"></p><p class="MsoBodyTextFirstIndent" style="text-align:center;"><span><img src="file:///C:\Users\ADMINI~1\AppData\Local\Temp\ksohtml6364\wps1.png" alt=""></span><img class="image_resized" style="width:76.56%;" src="https://omo-oss-image.thefastimg.com/portal-saas/pg2025102117473232840/cms/image/a244a9fb-ceae-4e18-a18a-efd137f78545.png" alt="" height="521" width="695"></p><p style="text-align:center;"><span>左:评价人员罗智,中:项目负责人保家超,右:受评企业代表</span></p>